Two immobilization procedures were tested and compared considerin

Two immobilization procedures were tested and compared considering the amount of the immobilized P35S probe and the extent of the hybridization reaction with the target oligonucleotide. In wet chemistry procedure,

the interaction between the thiol and gold for the immobilization of a thiolated probe was employed. Direct surface functionalization of piezoelectric quartz crystals were achieved in 13.56 MHz plasma polymerization reactor utilising ethylenediamine (EDA) precursors for the immobilization of amined probes. Results indicated that immobilization of a thiolated probe provides better immobilization characteristics and higher sensitivity for the detection of the hybridization reaction. The thiolated probe was used for the detection of P35S STI571 sequence in PCR-amplified DNAs and in real samples of pflp (ferrodoxin like protein)-gene inserted tobacco plants. Fragmentation of the genomic DNAs were achieved by digestion with restriction endonucleases and ultrasonication. The results obtained from the fragmented genomic DNAs demonstrated that it is possible to detect the target sequence directly in non-amplified genomic DNAs by using the developed QCM-based DNA biosensor system. The developed

QCM-based DNA biosensor represented promising results for a real-time, label-free, direct detection of DNA samples for the screening of GMOs. (C) 2008 Elsevier B.V. All rights reserved.”
“In this article we present an update learn more on the applications of chemiluminescence coupled with flow injection analysis for the determination of pharmaceuticals. Several reported applications of flow and sequential injection chemiluminescence (FI-CL/SI-CL) in pharmaceuticals concern greatly on quality control, investigation of dissolution of particular formulations or process control of production of pharmaceuticals and their presence in physiological fluids. A number of advances in the development of FI-CL methods have been reported MEK162 manufacturer in recent years on pharmaceutical analysis.

In the present review we have covered six years period from Jan-2007 to Dec-2012 discussing FI-CL/SI-CL in the liquid phase as an analytical tool

for the determination of pharmaceuticals in diverse samples. We reviewed the methods as per general CL reaction involved with the help of 321 cited references. Interesting features of the FI-CL methods like the use of molecularly imprinting polymers for selectively and specially designed cells/microfluidic devices or lab-on-a-chip for better detection or sensitivity were also presented.”
“The magnetic and magnetostructural properties of the polycrystalline Ce(Fe0.975Ga0.025)(2) have been investigated as a function of temperature and magnetic field. In Ce(Fe0.975Ga0.025)(2) the magnetic transition from antiferromagnetic (AFM) to ferromagnetic (FM) state is accompanied by a structural transformation from rhombohedral to cubic structure.